Red sprinkler mains and valve sets running through a commercial building under fit-out

Get your sprinklers, risers and fire pumps tested and certified

Working across England from Kettering, to BS 9990 and BS EN 12845.

  • BRE Global Certification and UKAS Management Systems 0007
  • LPCB, Loss Prevention Certification Board

The two certifications insurers check. Working across 18 towns in England, from Kettering.

Step 1 of 3

Book a free survey

Three questions. No survey fee, no obligation.

What do you need?

  • 4 years of active trading
  • 100+ projects completed
  • 24/7 emergency call-out

Built around your building

The standard is the same everywhere. The hazard classification is not: a cinema sits three groups above a hospital, and food production spans three on its own. Pick yours.

Sprinkler main being run across a warehouse roof Warehouses and distribution OH1 to OH4, or High Hazard for storage Racking, storage height and what you keep in it decide the design. Get those wrong and the system is under-designed from day one. What this building needs A high-rise residential block with rows of balconies Blocks of flats BS 9251, residential Above 11 metres a new block needs them. Everything after that is the maintenance record, and it is what a managing agent gets asked for. What this building needs A period brick office building between modern glass towers Offices Light Hazard, or at least OH1 Multi-let buildings where the landlord holds the common parts and the tenant holds the demise. Most of the trouble is the line between them. What this building needs Sprinkler control valve sets on a plant room wall Care homes BS 9251, residential A building full of people who cannot self-evacuate, on a maintenance regime that has to be provable without disrupting them. What this building needs A multi-storey institutional building with banded windows Hospitals and healthcare At least OH1 Ordinary Hazard Group 1, and the only building type on this list where nobody can be asked to leave. Isolation planning is the whole job. What this building needs A sprinkler alarm valve set in a plant room Cancer treatment centres At least OH1, with specialist rooms A hospital classification wrapped around rooms no general contractor should touch: MRI, radiotherapy bunkers and aseptic pharmacy. What this building needs Red brick school buildings with a clock tower and stepped gables Schools and colleges At least OH1 The DfE stopped pointing at BB 100 in January 2026. What replaced it sets a height threshold, three building types that always qualify, and a maintenance regime for everything already installed. What this building needs An aerial view of an open-air shopping centre and its car parks Shopping centres At least OH3 Ordinary Hazard Group 3, and a building whose design changes every time a unit is re-let. The system rarely keeps up on its own. What this building needs A bottling line and stainless process pipework in a food plant Food processing OH1 to OH3, by product Three different hazard groups live under this one heading. Which one you are in depends on what you make, not on the size of the shed. What this building needs A neon cinema sign on a painted period facade Cinemas and theatres At least OH4 Ordinary Hazard Group 4, the highest of the ordinary groups. Most people assume an auditorium is a low risk. The standard does not. What this building needs A classical gallery building with a columned portico and dome Museums and galleries At least OH2 The objection is always water on the collection. The arithmetic runs the other way, and it is worth seeing why before the decision gets made for you. What this building needs

Every building type, and its classification side by side

Project photographs, from our own sites.

See all 52
Large alarm valve set with gauges and trim in a plant room
Three sprinkler control valve sets installed on a plant room wall
Electric fire pump set and jockey pump in a plant room
Prefabricated sprinkler pipework and brackets laid out ready to install
Sprinkler main being run out across a warehouse
Valve assembly and red pipework in a pump house
External riser running up a building facade
Sprinkler design drawings open on site
Sprinkler mains in an undercroft car park
Valve set and pressure vessel in a pump house
Sprinkler mains delivered to site
Two dry riser breeching inlets in stainless steel cabinets, twin instantaneous couplings with blank caps and chains
Two brass wet riser landing valves with red handwheels and capped outlets on galvanised risers
A bank of four sprinkler alarm valve sets on orange risers in a plant room, with gauges and tamper switched valves
A packaged fire pump house with the door open, showing a red Clarke diesel pump set and its exhaust stack
A large bolted sectional galvanised sprinkler tank with its overflow pipe and riser

Large alarm valve set with gauges and trim in a plant room

We work across England, from Kettering.

Most weeks that means the Midlands, the Home Counties and London, which is the ring on the map. For a project worth the journey, ask us anywhere in England.

The survey is free inside the ring and there is no travel charge added afterwards. Outside it, ring and we will tell you honestly whether we are the right people. Hover a town below to find it on the map, or open it for what we do there.

Where Sentry Sprinkler Protection works A map of central and southern England marking Kettering, where the company is based, a 100 mile ring around it covering the towns it works in every week, and the towns served. Work is taken across England. Kettering Leicester Peterborough Birmingham London

Specialists, not a general contractor.

Water-based suppression is the whole business, and you get Marius Bucur on the phone rather than a call centre.

  • No fire alarms
  • No extinguishers
  • No fire doors or passive work
Three sprinkler control valve sets installed on a plant room wall
Three sprinkler control valve sets installed on a plant room wall
Electric fire pump set and jockey pump in a plant room
Electric fire pump set and jockey pump in a plant room
Sprinkler main being run out across a warehouse
Sprinkler main being run out across a warehouse
52 photographs from our own jobs See all
  • Specialism Water-based suppression only
  • Where we work England, from Kettering
  • Cover 24/7 emergency call-out
  • Standards BS EN 12845 · BS 9251 · BS 9990

Approved, and audited on a schedule.

Two certifications, and the first one is the reason we could apply for the second. ISO 9001 is a precondition for LPCB approval, so this is a sequence rather than a collection.

BRE Global Certification and UKAS Management Systems 0007

ISO 9001:2015

Certified by BRE Global, accredited by UKAS

An audited quality management system. It means the way a job is planned, recorded and signed off is itself inspected by somebody independent, on a schedule.

LPCB, Loss Prevention Certification Board

LPCB approved

Loss Prevention Certification Board

The approval UK insurers look for on sprinkler work. A system installed by an LPCB approved contractor counts as genuine risk mitigation on your policy; one installed by anybody else may not.

Working to BS EN 12845, BS 9251 and BS 9990. If your insurer or fire risk assessor wants the certificates themselves, ring us and we will send them over.

Four intervals. Miss one and the record has a hole in it.

These are the responsible person's, not the landlord's and not the managing agent's. The duty follows whoever controls the premises.

  1. Weekly

    Sprinkler system checks

    Water and air pressure gauges, alarm motor test, pump start test where fitted.

    BS EN 12845
  2. Quarterly

    Flow switch and alarm testing

    Proving that water movement actually raises an alarm, not just that the valve opens.

    BS EN 12845
  3. Six-monthly

    Dry and wet riser inspection

    Visual check of inlets, landing valves, cabinets, caps, signage and access.

    BS 9990
  4. Annually

    Riser pressure test and full service

    Risers charged to 12 bar and held for 15 minutes. Full sprinkler service and pump performance test.

    BS 9990 · BS EN 12845

The questions we get asked first

Four that come up on nearly every first call. There are thirty more on the questions page, and each service page answers the technical ones for that work.

What makes a sprinkler specialist different from a general fire safety contractor?

A general contractor covers eleven trades and subcontracts the ones they do not do. We do one: water-based suppression. That means the engineer who arrives has seen your type of valve set before rather than reading the manual in your plant room, and it means we are LPCB approved for the work rather than holding a general accreditation that covers it loosely.

Why are there no prices on this website?

Because a price set before anyone has seen the building would be wrong, and you would plan around it. Two warehouses that look identical from the road can differ by thousands once you count the valve sets, the pump arrangement, the height of the risers and how hard the plant is to reach. So we survey instead. It is free, it takes an engineer rather than a salesperson, and you get a firm figure in writing that holds for thirty days.

Is the free survey genuinely free?

Yes. No survey fee, no obligation, and no pressure afterwards. We look at the building, then put a fixed price in writing. If the answer is that you do not need what you thought you needed, that is what the survey will say.

How quickly can somebody actually come out?

The office is on the phone Monday to Friday, 7am to 5pm, and most enquiries get a call back the same working day. Outside those hours the same number reaches our emergency line. That line is for emergencies rather than quotes: a discharging head, a leaking main, a pump that will not start, a riser that has failed its test. How fast an engineer reaches you depends on where the building is and what has failed, so you get a realistic time on the call rather than a headline figure we might miss.

Tell us the building. We will tell you what it is due.

No survey fee to find out where you stand. Describe the site and we will tell you which intervals apply and what the visit involves.

Based
37 Dickens Drive, Kettering, NN16 9EG
Covering
Kettering · Corby · Wellingborough · Northampton · Rushden · Daventry · Market Harborough · Bedford and England, from our base in Kettering
Office hours
Monday to Friday, 7am to 5pm. Emergency line any hour.

What do you need?
    Who do we come back to?

    If it is urgent, ring rather than write. We are on the phone Monday to Friday, 7am to 5pm, and outside those hours the same number reaches the emergency line.

    Or send it straight to us

    Or just ring 07927 555475 and talk it through. Mon to Fri, 7am to 5pm. Emergencies any hour.