Dry riser testing in London

Dry riser testing in London: six-monthly inspections and annual pressure tests under BS 9990, access planned before the day, certificate left after it.

Dry riser inlet cabinets at street level, the first thing checked during dry riser testing in London
Dry riser inlet cabinets, photographed on one of our jobs.
  • ISO 9001, the certification insurers look for
  • Free survey, fixed price in writing, no travel charge
  • Office Monday to Friday, 7am to 5pm; emergency line any hour

Dry riser testing in London means the six-monthly visual inspection and the annual pressure test under BS 9990, on the densest stock of tall buildings in the country. Above 18 metres a building needs a fire main, so residential towers, office blocks and hotels across the city carry one. We plan the access before the day and leave a certificate after it. Sentry Sprinkler Protection does this work across England from its base in Kettering, ISO 9001 certified.

What each visit covers

  • Six-monthly: the inlet cabinet, inlet valves and caps, every landing valve, the air release valve, the drain and the signage, checked floor by floor.
  • Annually: the riser filled with water and held at 12 bar for 15 minutes, with every landing valve opened and closed under pressure.
  • Missing caps, seized valves and damaged cabinets photographed and listed, with a price per item.
  • A certificate for the building file on the day.
A dry riser landing valve in a stair lobby

Planned around the building, not the van

In central London the test is usually the easy part. Parking, permits, goods lifts and building management approval decide whether it happens, so we agree them in writing before the day. Where a lobby or a stair is busy in office hours, the pressure test goes early or late.

After the pressure test the riser is drained down, and the inlet and landing valves are left closed and capped.

Towers with more than one regime

Many London residential and mixed-use towers have a dry riser, a BS 9251 sprinkler system and, above 50 metres, a wet riser too. Each has its own interval. We test them on one schedule, so a managing agent has one date and one record per block.

In a higher-risk building under the Building Safety Act those records belong in the golden thread of information, so every certificate names the riser, the floors and the result.

Dry riser pipework running through a service void

Across Greater London

Dry riser testing in London is not only a central London job. Outer boroughs such as Haringey, Barnet, Croydon and Ealing have their own stock of residential blocks, schools and offices over 18 metres, and each riser is tested to the same BS 9990 intervals as a City tower. Visits are grouped by area, so a block in an outer borough keeps a fixed six-monthly date.

If the riser fails

London is roughly seventy-five miles from our base, so every visit is a planned job. A riser that fails is not left as a line on a report: the defects are priced item by item, repaired on a return visit, and the riser is tested again.

Dry risers, on our jobs

4 photographs of this exact work, from the owner's own sites. Tap any of them.

The full gallery
  1. SurveyFree, and we walk the building
  2. Fixed priceIn writing, with the standard named
  3. First visitDone, recorded and certificated

or call 07927 555475

From first call to certificate

Four steps, the same on every job.

  1. A sprinkler layout drawing marked up on site during a survey
    01

    Free survey

    We look at the building and its records, and tell you what it is due.

  2. A sprinkler installation drawing open on a laptop on site
    02

    Fixed price in writing

    Every item priced line by line. No survey fee, nothing added afterwards.

  3. An engineer installing sprinkler pipework from a scissor lift
    03

    The work, on your dates

    Isolation agreed before anyone arrives, kept as short as the job takes.

  4. A bank of sprinkler alarm valve sets with gauges in a plant room
    04

    Certificate and record

    A certificate and a photographed defect list, ready for your insurer.

  5. Start

    Book the free survey

    Tell us the building. We will tell you what it is due.

    Book a free survey

Switching from another contractor?

It happens often, and mid-year too. You do not have to wait for the old contract to run out to find out where your dry riser stands.

  1. Send what you have

    The last service report, the certificate, or a photo of the valve set. Whatever you have is enough to start.

  2. We survey before we quote

    What is installed, the standard it was designed to, whether the pumps make their duty and what the last reports found. Free, and written down.

  3. A clean record from our first visit

    If the old records are thin we say so and start a clean record, rather than sign off work we did not see.

When is your next visit due?

Pick the system and the month a contractor last came. You will see each routine, the date it falls due and anything that is already late.

Weekly checks are your own team's, logged on site. Our free weekly test log covers them on one page.

1 · The system

2 · The last contractor visit

Pick a month and a year to see your dates.

  • Every 6 months Six-monthly inspection Inlets, landing valves, cabinets, caps and access
  • Every 12 months Annual pressure test Charged to 12 bar and held for 15 minutes
  • BS 9990

Counted from the visit you picked. If that was not the annual service, the annual may fall sooner. Your insurer or fire strategy can ask for more.

Book the visit or ring 07927 555475

Free survey · fixed price in writing

Tell us what you need. We will tell you what it takes.

Four quick taps and your details. A free survey and a fixed price in writing, with no survey fee and no obligation.

Call 07927 555475

Mon to Fri, 7am to 5pm. Emergencies any hour.

What do you need?

Pick one. The next questions follow from it.

What kind of building is it?
How tall is the building?
What is happening?
Which part needs looking at?
Where is the project?
When is it due?
How soon do you need us?
Who do we ring back?

Usually the same working day. We never share your details.

No survey fee, no obligation. ISO 9001:2015 certified.

5.0 on Google

4 reviews, and every one of them five stars.

  • Lewis W. Sprinkler installation, warehouse

    Had them install a full sprinkler system across one of our warehouses, and couldn't be happier. They were professional from start to finish and the on-site team were genuinely friendly to work with. […] Highly recommend if you would need your building or warehouse properly fire-protected.

    5 stars on Google

  • Mike C. Weekly maintenance, testing and repair

    Sentry Sprinkler Protection have recently taken over the weekly maintenance, testing and repair of the […] sprinkler equipment. They are providing a excellent service, good value and they are also very helpful when on site.

    5 stars on Google

  • Sam E. Sprinkler pipework installation

    Couldn't recommend [Sentry] enough. Their work ethic, consistent efficient install of the pipework and overall approach to a project should be something every sub-contractor strives to mirror. Marius is incredibly approachable and methodical in his work with laydown areas kept very neat and tidy and all work carried out in a safe manner.

    5 stars on Google

Questions about dry riser testing in London

How often does a dry riser in London need testing?

The same as anywhere in England: a visual inspection every six months and a pressure test every year under BS 9990. What is different in London is how many buildings are tall enough to have one, and the planning it takes to get access.

Do you test dry risers in outer London boroughs as well as central London?

Yes. Dry riser testing covers Greater London, not just the centre. Visits are grouped by area, and the address is confirmed before anything is booked.

Can you test the risers across a portfolio of London blocks?

Yes. Every riser goes on one schedule, so each block has a known test date, and the certificates come back in one format for the whole portfolio.

What usually makes a London dry riser fail its test?

Small things: a landing valve seized shut, a perished gasket that weeps at pressure, a missing inlet cap or a drain valve left open. Each is photographed and priced, and the riser is retested after the repair.

What happens when you ring

You talk to Marius Bucur, who runs the company and prices the work. Not a call centre.

07927 555475

Mon to Fri, 7am to 5pm. Emergencies any hour.

Rather type?
  1. A few plain questions

    Usually four: what the building is, what system it has, when it was last serviced and the postcode. If you do not know some of it, that is normal.

  2. A straight answer

    Whether it is a job for us. If a building would be better served by someone closer, we will tell you that too.

  3. A free survey, on your dates

    Then a fixed price in writing, line by line. No survey fee, no obligation, nothing added afterwards.